Your present location: Service Support>> Common Problem >> Member inspection methods

1. Common test items and the reference value table

No.

Measuring  Project

Instrument

Stalls

Normal reference values

Measurement methods

1.1

Output load voltage

Multimeter

Direct-currentDC

200V

M2 type:70~65V

E5type:80~95 V

4.0 Series:80~95V

After the machine powered by test leads to measure the output of copper terminals or quick connect outlet ends of the voltage value

2.1

Cooling fan

Multimeter

Resistance

2k

220V type: 280Ω or more

380Vtype:592~850Ω

Power-off state, measured with a cooling fan test leads two input resistance between power line

3.1

Input rectifier bridge

Multimeter

Diode

Pipe file

E and D:650-800

E and A:400

E and B:400

E and C:400

Power-off state, with the test leads (black) (E +) terminal, test leads (red) are connected to D, A, B, C terminal. If the value of E, D ends is about 400 or infinite rectifier bridge can be judged bad

4.1

Control transformer

Multimeter

AC AC

200V

22V

(Such as stalls for the resistance 2k files, display value 0.04)

Power-off state, the control variable associated with the intelligent control module is unplugged red line with test leads measure the voltage between the two jack socket

5.1

Breaker/p>

Multimeter

Diode

Pipe file

Display "0" or chirping sound

Power-off state, the resistance between the circuit breaker is closed, the detection of the input and output terminals of the circuit breaker corresponding two holes

6.1

Encoder means

Multimeter

Diode

Pipe file

Display "0" or chirping sound

Power-off state, with the test leads connected to the + encoder black jack, negative respectively, then green, blue line socket, rotary encoders, shows "0" or chirping sound indicates normal, followed by red socket, according to the encoder, display "0" or chirping sound indicates normal

7.1

 

 

Whole freewheeling parts

 

 

 

 

Whole freewheeling parts

 

 

Multimeter

 

 

 

 

Multimeter

 

Diode

Pipe file

 

335 or 1

Power-off state, multimeter test leads connected to the output of the positive and negative, the negative pole output correct number of poles, the value 335, which in turn measured values compared to the normal value of 1; if the value is 0 or tweet namely rectifier wear

Resistance profile20k

1019 or 1

Power-off state, with a multimeter test leads connected to the positive output upright pole, test leads connected to the output correct the negative pole, a value of 1, in turn measured value is 1019; if the value is 0 or tweet, namely rectifier wear.

8.1

  Intelligent control module

Driving voltage

Multimeter

AC AC

20V

14.4V~19.3V

Energized the full bridge output D, E socket ends and the motherboard and connected IGBT phase two black and two red and orange lines and unplug the drive, then were measured square plate IGBT drive two orange jack black line and the voltage value between the two red and white lines

9.1

  Intelligent control module

MPU

Voltage

Multimeter

DC DC

20V

7.9V

Energized state, the control board were measured 4 feet and 5 feet on the ground voltage value (closest to the pin end of the pulse transformer 1 foot, flat welding fins on the ground), you need to intelligent control module from the Remove the shield plate machine, measuring pin on the back. This operation is very dangerous, improper operation will cause a short circuit, electric shock!

 

2  IGBTInverter means for detecting
① IGBTSingle-tube measurement:

(IGBT control schematic)

Multimeter Pen+

Multimeter Pen-

Normal value

G

D

>1400 or 1

D

G

>1400 or 1

G

S

>1400 or 1

S

G

>1400 or 1

D

S

>1400或1

S

D

400

IGBT single tube has G, D, S three feet, the shortest one is G foot, the other foot followed by D and S feet. Between a normal single tube, G and D foot foot, foot to the S pin between G not pass a value with a multimeter diode range measuring 1 or & gt; 1400, S foot to foot single conduction between D, with a multimeter diode range measuring value of about 400. As between any two points is 0 (short circuit), it is determined that the measurement of a single tube is damaged.
②IGBT module measures:

+=

(Module driver board)

(IGBT module schematic)

 

IGBT module 1 feet to tap the high-frequency transformer, 2 feet to the negative full-bridge, full-bridge 3 feet to the positive electrode, 4,5 and 6,7 respectively connected module driver board, such as between any two points is measured using the multimeter diode file 0 (short circuit), it is determined that damage to the module, between the foot values in the following table:

Multimeter pen+

Multimeter pen-

Normal value

1

2

>1400 or 1

2

1

350

1

3

350

3

1

>140 or 1

2

3

700

3

2

>1400 or 1

4

5

>1400 or 1

5

4

>1400 or 1

6

7

>1400 or 1

7

6

>1400 or 1

 

5.11  Correct insertion methods IGBT inverter component cable

Easy special flow welder when replacement IGBT, IGBT drive line from two intelligent control board and a set of drawn lines to correct phase IGBT inverter plugged into the unit, but leads to a thermistor signal lines from IGBT plugged into intelligent control panel, if the wrong plug can cause damage welder (Figure P14 mode II). Vintage IGBT will be more than a thermistor signal line socket, you need to connect to a smart black signal line through a set of control board, other lines unchanged (Figure P14 one way). There are two kinds of ways:

One way: Vintage IGBT inverter unit socket

Second way: Latest IGBT inverter unit socket